Biochemistry

Biochemistry Analyzer B2000

Biochemistry Analyzer B2000 Immuno assay system is based on the principle of magnetic particle, glow Chemiluminescence technology…. It is meant for the diagnosis of Thyroids, Fertility,Cardiac,Prenatal screening, Glyco metabolism, Bone metabolism,ToRCH,Tumormarkers, Anaemia, Inflammation monitoring,Kidney function,Infectious like HIV,HBsAG,HCV & Syphilis..etc. It is a fully automated Random access analyser with true stat facility for sample. The throughput is up to 100 Tests/hour. 100 samples with continuous loading facility and 24 different reagents can be loaded at a time. Reagent Area is provided with cooling facility.Liquid level and clot detection facility available for sample/reagent probes. Reagent kits are Liquid stable and barcoded for identification . Calibrators and Internal quality controls are provided. Samples identification through Bar code scanner. System can connect with LIS. Auto dilution facility with preferable ratios available. Real time calibration curve used for assay calibration. Wide menu with special parameters available like TB IGRA,AMH,Prenatal,17-OH progesterone, HS CRP, Aldosterone, Angiotensin , Plasma Renin Activity , Hepatic Fibrosis , Reverse T3 etc.

4.5

Specification

Sample Testing Speed Maximum throughput 2000 tests/hour (1 analysis module) Optional electrolyte module,
maximum throughput 2400 tests/hour;
Maximum throughput 4000 tests/hour (2 analysis modules) Optional electrolyte module,
maximum throughput 4800 tests/hour;
Maximum throughput 6000 tests/hour (3 analysis modules) Optional electrolyte module,
maximum throughput 7200 tests/hour;
Maximum throughput 8000 tests/hour (4 analysis modules) Optional electrolyte module,
maximum throughput 9600 tests/hour.
Number of Simultaneously Analyzed Items Up to 91 items can be analyzed simultaneously (single analysis module).
Analysis Method Endpoint method, fixed-time method, rate method, supports single/double, three/four reagent testing and single, double wavelength.
Emergency Emergency Priority.
Number of Emergency Positions 5 samples can be added each time (5 sample positions/rack, can be added cyclically).
Sample Management System Can accommodate up to 305 samples (5 sample positions/rack, including emergencies, can be added cyclically).
Sample Tube Type Sample tubes with a diameter of 13/16 mm, 2 mL microcups.
Reagent Positions Has two reagent trays, each reagent tray has 90 reagent positions (70 mL reagent bottles), totaling 180 reagent positions.
Reagent Refrigeration Reagent refrigeration 2°C–8°C (supports 24-hour uninterrupted refrigeration).
Sample Volume 1.5–35 µL, 0.1 µL increment.
Reagent Volume R1: 15–250 µL, 0.5 µL increment;
R2: 15–250 µL, 0.5 µL increment.
Sample Needle Liquid level detection, clot detection (needle clogging), collision prevention detection, air suction detection.