Autobio Autolumo A2000 Plus
AUTOLUMO A2000 Plus Immuno assay system is based on the principle of magnetic particle, glow Chemiluminescence technology…. It is meant for the diagnosis of Thyroids, Fertility,Cardiac,Prenatal screening, Glyco metabolism, Bone metabolism,ToRCH,Tumormarkers, Anaemia, Inflammation monitoring,Kidney function,Infectious like HIV,HBsAG,HCV & Syphilis..etc. It is a fully automated Random access analyser with true stat facility for sample. The throughput is up to 100 Tests/hour. 100 samples with continuous loading facility and 24 different reagents can be loaded at a time. Reagent Area is provided with cooling facility.Liquid level and clot detection facility available for sample/reagent probes. Reagent kits are Liquid stable and barcoded for identification . Calibrators and Internal quality controls are provided. Samples identification through Bar code scanner. System can connect with LIS. Auto dilution facility with preferable ratios available. Real time calibration curve used for assay calibration. Wide menu with special parameters available like TB IGRA,AMH,Prenatal,17-OH progesterone, HS CRP, Aldosterone, Angiotensin , Plasma Renin Activity , Hepatic Fibrosis , Reverse T3 etc.
Specification
| Throughput | 200 Tests / Hrs |
|---|---|
| Time to 1st Result: | 21 mins |
| RV Loading Capacity: | 80 × 2 pcs |
| Sample Loading Capacity: | 60 samples with 1 STAT channel |
| Sample Pipette Volume: | 5–150 µL |
| Sample Dilution Factor: | Upto 2601-fold |
| Detection Features: | Liquid Level Detection and Clot Detection |
| Onboard Reagent Capacity: | 25 Packs |
| Onboard Reagent Storage: | Independent refrigerating system |
| Reagent Replacement: | Real-time replacement of Reagent by Appointment |
| Consumables Monitoring: | Residue calculation (LED Monitor and Software Monitor) |
| Substrate: | Substrate A + B |
| Substrate Volume: | 100 mL for each |
| Substrate Switching: | 2 sets of substrates available on board by automatic switching |
| Carry-over: | < 1 ppm |
| Reaction Model: | 1 step and 2 steps |
| Size (W × D × H): | 1200 × 736 × 635 mm |
| Weight: | 183 kg |
| Sample Identification: | Barcode reader recognition or analyser auto-numbered |
| Connectivity: | LIS connection, auto-read sample information available |
| Technology: | Uses Chemiluminescent microparticle immunoassay technology |
| Data Handling: | RFID tag / barcode with built-in master curve |
| Calibration Stability: | 28 days |
| Aspiration Precision: | Precisely controlled syringe motors for high precision aspration |
| Probe Cleaning: | Efficient interior probe wash with system wash |
| Enhanced Cleaning: | Programmable enhanced probe wash with detergent |
| Detection System: | Consistent performance reliability with enhanced PMT detection system |
| Mixing Method: | Eccentric non-contact swirl mixing |